The Smith Meter Model G6 is a 6-inch, steel, double-case, straight-through rotary vane positive displacement (PD) meter used for custody transfer, batching, blending, dispensing and inventory control of petroleum products, oils, solvents, chemicals and similar liquids. Smith's offset inlet and outlet nozzles keep pressure drop across the measuring chamber low, which minimizes slippage and preserves accuracy, and a high-torque calibrator adjusts registration in 0.05% steps.
Key specifications
- Size: 6 in, ANSI B16.5 raised-face flanges
- Max flow, standard trim: 1,000 USGPM (3,750 L/min) continuous; 1,200 USGPM (4,600 L/min) intermittent (clean refined products)
- Max flow, all-iron / LPG trim: 750 USGPM (2,800 L/min)
- Linearity: ±0.15% typical over the rated range (minimum flow depends on viscosity)
- Repeatability: ±0.02%
- Pressure ratings (at 100 °F): G6-S3 Class 150 (285 psi); G6-S5 Class 300 (300 psi); G6-S6 Class 300 (740 psi); G6-S7 Class 600 (1,480 psi); G6-S8 Class 900 (2,220 psi)
- Viscosity: 400 mPa·s standard; to 2 Pa·s with high-viscosity clearances
- Temperature: -20 to 150 °F standard clearances; to 200 °F high-temp; to 400 °F all-iron trim (seal dependent)
- Meter gearing: 5 US gal, 1 barrel or 5 dekaliters per calibrator revolution
- Materials: Steel housing; iron, steel, stainless and aluminum internals (standard trim); Buna-N, FKM (Viton) or PTFE seals; LPG and all-iron trims
- Options: High-viscosity and high-temperature clearances, NACE MR0175 construction, ASME Section VIII vessel on G6-S3; strainer, air eliminator, valves, counters, printers, pulse transmitters and ATC/ATG accessories
How to read the model code
Example: KG6S3GBS00. Read the code left to right; each position selects one option:
- Position 1 (Catalog code): K = catalog code
- Positions 2-3 (Model / size): G6 = 6 in
- Position 4 (Flow path): S = straight-through
- Position 5 (Pressure class, RF flanges): 3 = Class 150 (285 psi); 6 = Class 300 (740 psi); 7 = Class 600 (1,480 psi); 8 = Class 900 (2,220 psi)
- Position 6 (Meter gearing): G = gallons; B = barrels; D = dekaliters; I = imperial gallons; P = pounds (consult factory for I and P)
- Position 7 (Seals): B = Buna-N; V = FKM; T = PTFE; L = low-temperature FKM
- Position 8 (Trim): S = standard; A = all iron; L = LPG
- Position 9 (Temperature compensation): 0 = none; A = ATC (factory-set); B = ATG (field-adjustable)
- Position 10 (Special requirements): 0 = standard; P = EU PED (Ellerbek-built); C = CRN + low-temp material; L = low-temp material
Pricing and lead time are quoted per configuration. Send the model code (or the details above), product, flow range, and pressure/temperature to Flow Measurement Services for a quote. Specifications summarized from Smith Meter bulletin SS01014; confirm current data with the factory before ordering.
Smith Meter (formerly FMC Technologies / TechnipFMC Measurement Solutions), now manufactured by Guidant. Flow Measurement Services supplies and services Smith Meter equipment.