The Smith Meter Model K12 is a 12-inch, steel, double-case, straight-through rotary vane positive displacement (PD) meter in the Crude Transportation (CT) Series of large PD meters. CT Series meters use lightened blades, full-width wear strips and tungsten carbide roller pins for long service in harsh crude oil, and are equally suited to refined products for custody transfer, batching, blending and leak detection.
Key specifications
- Size: 12 in, ANSI B16.5 raised-face flanges
- Max flow, standard trim: 7,200 BPH (1,140 m³/h) continuous
- Max flow, all-iron / LPG trim: 5,400 BPH (855 m³/h)
- Linearity: ±0.15% typical over the rated range (minimum flow depends on viscosity)
- Repeatability: ±0.02%
- Pressure ratings (at 100 °F): K12-S3 Class 150 (285 psi); K12-S6 Class 300 (740 psi); K12-S7 Class 600 (1,480 psi)
- Viscosity: 200 mPa·s standard; to 2 Pa·s with high-viscosity clearances
- Temperature: -20 to 115 °F standard clearances; to 200 °F high-temp; to 400 °F all-iron trim (seal dependent)
- Meter gearing: 1 barrel or 1 hectoliter per calibrator revolution; 50 gal special
- Materials: Steel housing; iron, steel, stainless and aluminum internals (standard trim); Buna-N, FKM (Viton) or PTFE seals; LPG and all-iron trims
- Options: High-viscosity and high-temperature clearances, NACE MR0175 construction, ASME Section VIII vessel on K12-S3; strainer, air eliminator, valves, counters, printers, pulse transmitters and ATC/ATG accessories
How to read the model code
Example: KK12S3BBS00. Read the code left to right; each position selects one option:
- Position 1 (Catalog code): K = catalog code
- Positions 2-3 (Model / size): K12 = 12 in
- Position 4 (Flow path): S = straight-through
- Position 5 (Pressure class, RF flanges): 3 = Class 150 (285 psi); 6 = Class 300 (740 psi); 7 = Class 600 (1,480 psi); 8 = Class 900 (2,220 psi) per catalog guide
- Position 6 (Meter gearing): G = gallons; B = barrels; D = dekaliters; I = imperial gallons; P = pounds (consult factory for I and P)
- Position 7 (Seals): B = Buna-N; V = FKM; T = PTFE; L = low-temperature FKM
- Position 8 (Trim): S = standard; A = all iron; L = LPG
- Position 9 (Temperature compensation): 0 = none; A = ATC (factory-set); B = ATG (field-adjustable)
- Position 10 (Special requirements): 0 = standard; P = EU PED (Ellerbek-built); C = CRN + low-temp material; L = low-temp material
Pricing and lead time are quoted per configuration. Send the model code (or the details above), product, flow range, and pressure/temperature to Flow Measurement Services for a quote. Specifications summarized from Smith Meter bulletin SS01020; confirm current data with the factory before ordering.
Smith Meter (formerly FMC Technologies / TechnipFMC Measurement Solutions), now manufactured by Guidant. Flow Measurement Services supplies and services Smith Meter equipment.