top of page

The Smith Meter UPCC (Universal Performance Curve Compensator) is a microprocessor-based turbine meter preamplifier for Smith Meter MV Series multiviscosity turbine meters. It applies each meter's factory meter-factor versus velocity/viscosity curve in real time, using a constant viscosity, temperature-inferred viscosity, a 4-20 mA viscosity signal or a direct Solartron viscometer head. It also squares up the pickup signal for long cable runs and works as a small flow computer with rate, batch and cumulative totals.

Key specifications

  • Viscosity input: Constant value, temperature/viscosity (RTD), 4-20 mA proportional to viscosity, or Solartron viscometer head (24 VDC supply required)
  • Power: 12-24 VDC ±10%, under 250 mA at 24 V
  • Signal input: Sinusoidal pickup (70 mVp-p sensitivity) or square wave; to 2,000 Hz
  • Inputs: 3 status inputs, four-wire 100-ohm PRTD, one 4-20 mA input
  • Outputs: 4 push-pull pulse outputs (2 raw, 2 programmable: compensated, high-resolution or quadrature), 2 open-collector switch outputs, 2 4-20 mA outputs
  • Communications: EIA-232 or EIA-485 (DIP selectable), 1,200-19,200 bps, Modbus ASCII/RTU
  • Environment: -58 to 158 °F (24 VDC needed below -4 °F); 0-95% RH non-condensing
  • Approvals: UL/cUL Class I Groups C & D, AEx d IIB T6 IP66; ATEX/IECEx Ex d IIC T6 IP66
  • Cable distance: Up to 2,400 ft (#20 AWG), 3,800 ft (#18) or 6,000 ft (#16)

How to read the model code

Example: UPCC-XU-STD. Read the code left to right; each position selects one option:

  • Position 1 (Model): UPCC = Universal Performance Curve Compensator
  • Position 2 (Housing): XU = UL/cUL listed; XC = ATEX / IECEx certified
  • Position 3 (Firmware): STD = standard

When ordered with a new MV Series meter, the UPCC is specified in the meter catalog code (pickup position U or W, testing position C or D) so the meter is calibrated for viscosity compensation.

Pricing and lead time are quoted per configuration. Send the model code (or your application details), product, flow range, and pressure/temperature to Flow Measurement Services for a quote. Specifications summarized from Smith Meter bulletin SS02017; confirm current data with the factory before ordering.

Smith Meter (formerly FMC Technologies / TechnipFMC Measurement Solutions), now manufactured by Guidant. Flow Measurement Services supplies and services Smith Meter equipment.

Smith Meter UPCC Universal Performance Curve Compensator (Turbine Preamp)

‏0.00 US$السعر
مستثناة ضريبة |
الكمية
    FMS Logo White and Blue png.png
    • YouTube
    • LinkedIn
    • Instagram
    • Facebook
    • Twitter
    • Discord
    Daniel Measurement & Control, Emerson, Technip FMC Smith, Honeywell, Enraf, TopTech, Varec, Endress Hauser, Krohne, OPW, Excel Loading Systems, Emco Wheaton, Brodie, Faure Herman, Sensia, OMNI, ABB, Dynamic Flow Computers, Welker, Clif Mock, Ametek, Phase Dynamics, Titan Solutions, ASI Additive Systems Inc, Scully, GSI Gauging Systems, L&J, Blackmer, Viking Pump, FlowServe, Sulzer, DNOW, Sundyne, Griswold, ROPER, Corken, Smith Pumps, Gorman Rupp, John Crane, Goulds, Tuthill, Wilden, Yamada, Liquid Controls, FlowMD, Meter Engineers, TCS Total Control Systems, Veeder Root, Westech Industrial, SafeRack, Carbis, Safe Harbor, ErectaStep, Greenline, FlowTech, Fisher, Valtek, Rexa, Limitorque, Rotork, Dan Ex Western Valve, General Valve Twin Seal, Apollo Valve, IFC Islip, Asco, ATMOS, K-Patents, Flexim, Siemens, Allen Bradley, Wonderware, Swagelok, Magnetrol, CCS Custom Control Sensors, Armstron, Gammon, Fill Rite, Neptune, Liqua Tech, Hannay Reels, Coxreels, Wilcox Hose, Smart Hose, Jamison, Jenson Mixers, KEP Kessler Ellis Products, Precision Digital, API Coupler, Loading Arm, Truck Loading, Offloading, Additive Injection, Blending, PD Meter, Turbine Meter, Ultrasonic Meter, Coriolis Meter, Custody Transfer, NTEP Weights and Measures, Sampling, Mixing, Terminal Automation, PLC, RTU, Tank Gauging, Pipeline, Barge, Rail, 

    © 2026 Flow Measurement Services

    bottom of page