The Smith Meter Model 210 Valve is a 200 Series valve with two solenoid controls, used with a Smith Meter AccuLoad or microLoad preset controller for loading and unloading at truck racks, bulk plants and processing installations. A normally-open (30B) and a normally-closed (30A) solenoid in the control loop open, close or lock the main valve so the controller can hold a set flow rate and run a programmed low-flow start, high-flow and multi-stage shutdown. Needle valves between each solenoid and the main valve tune opening and closing speed and isolate the control loop for service. The design is fail-to-close. A 2" reduced-port version controls flow down to 3 GPM for renewable-fuels blending.
Key specifications
- Sizes / weight: 2" and 2" RP (46 lb), 3" (83 lb), 4" (136 lb), 6" (260 lb)
- Pressure rating / connections: Class 150 ASME, 285 psi (19.6 bar); Class 300 ASME, 300 psi (20.7 bar), at -20 to 100 °F
- Maximum viscosity: 200 SSU (40 mPa·s); above 200 SSU consult factory
- Elastomers / temperature: LS Buna (standard) or Buna-N: -20 to 200 °F (-28 to 93 °C); Viton: -20 to 350 °F (-28 to 177 °C)
- Solenoid voltage: Standard 120 VAC 60 Hz or 110 VAC 50 Hz; optional 240 VAC 60 Hz / 220 VAC 50 Hz, 24 VDC or 12 VDC
- Materials: Cast steel main valve with stainless steel, carbon steel, Ni-Resist and ductile iron internals; stainless steel solenoid valves (Viton-F standard, Buna-N, Chemraz); steel needle valves, tubing and fittings (stainless optional); optional ball valves on 4" and 6"
- Reverse flow / thermal relief: Reverse flow through the seat occurs when downstream pressure exceeds upstream by about 2-6 psig (size dependent); the optional 80B/07A check / pressure relief combination blocks reverse flow and relieves excess downstream pressure through the cover instead
- Pressure drop: Chart given for 2", 2" RP, 3", 4" and 6" (kerosene, 0.82 SG); 2" and 2" RP negligible below 50 GPM when not flow-limiting
How to specify / order
The bulletin has no position-by-position model code. To quote, send:
- Valve size (2", 2" reduced port, 3", 4" or 6") and flange class (150 or 300)
- Product, viscosity and the maximum and minimum flow rates (the pump must be able to reach the flow rate set in the preset)
- Elastomer choice (LS Buna, Buna-N or Viton) and solenoid voltage
- Options: 80B/07A check / pressure relief, stainless steel tubing, fittings or ball valves
- The preset controller in use (AccuLoad or microLoad)
Bulletin notes: The dimension table prints the 2" pilot-envelope dimension D as 7.5 in (140 mm); 7.5 in is about 191 mm. Related part listings on this store include the Model 210 N.O. solenoid part-number notices 645805-412 and 645805-413.
Pricing and lead time are quoted per configuration. Send the model code (or the details above) with your product and operating conditions to Flow Measurement Services for a quote. Specifications summarized from Smith Meter bulletin SS03009 Rev 1.1 (10/17); confirm current data with the factory before ordering.
Smith Meter (formerly FMC Technologies / TechnipFMC Measurement Solutions), now manufactured by Guidant. Flow Measurement Services supplies and services Smith Meter equipment.