The Smith Meter MPU 200 Series B is a single-path ultrasonic gas flowmeter for backup and check metering and for applications where reliability matters most. Its laterally offset straight path minimizes Reynolds-number effects and sits above the pipe centerline with a self-draining transducer port, making it well suited to wet gas and contaminated service where reflective designs struggle. It shares the MPU family's titanium flush-mount transducers, retraction under pressure and WinScreen diagnostics. For the newer MPU 200c, see the separate listing.
Key specifications
- Paths: 1 straight, laterally offset path; suited to wet and dirty gas
- Accuracy: ±1.5 to 2.5% depending on application
- Velocity range: 4-30": 0.4-30 m/s and higher
- Pressure / temperature: 1-275 bar a (to 3,990 psia, higher on request); gas -4 to 158 °F; ambient -13 to 140 °F
- Construction: Carbon or stainless steel spool; ANSI B16.5 RF or RTJ flanges Class 150 to 2500; titanium-encapsulated piezo transducers
- Power: 24 VDC (0.5 A) or 120/240 VAC, 12 W
- I/O: 2 digital inputs, 2 digital outputs, 4 pulse outputs to 5 kHz (single or dual quadrature), up to 2 analog in/out (4-20 mA or 1-5 VDC)
- Communications: 10/100 Ethernet (twisted pair or fiber), two RS-232/485 ports, Modbus RTU
- Approvals: UL/cUL Class I Div 1 Groups C & D; ATEX Eex d IIB T5
How to read the model code
Example: MPU-2-U-12-2-S-0-0-0-0-0. Read the code left to right; each position selects one option:
- Model: 12 = MPU 1200 (6-path); 8 = MPU 800; 6 = MPU 600; 2 = MPU 200
- Certification: U = US model, explosion-proof (UL/cUL); A = European model, ATEX
- Diameter: Nominal size in inches (06 = 6", 12 = 12", etc.)
- Flanges: 1 = 150; 2 = 300; 3 = 400; 4 = 600; 5 = 900; 6 = 1500; 7 = 2500
- Transducer: S = standard; R = retractable under pressure
- Optional interfaces: 0 = not required; F = fiber optic Ethernet (100Base-FL)
- Local display: 0 = not required; D = with local display
- Analog input: 0 = none; 1 = one 4-20 mA; 2 = two 4-20 mA; 3 = one 1-5 VDC; 4 = two 1-5 VDC (max 2 analog I/O total)
- Analog output: 0 = none; 1 = one 4-20 mA; 2 = two 4-20 mA; 3 = one 1-5 VDC; 4 = two 1-5 VDC
- Additional communication board: 0 = not required; C = with additional board
Include the catalog code on the purchase order. Submit gas composition, pressure, temperature and flow range for sizing.
Pricing and lead time are quoted per configuration. Send the model code (or your application details), product, flow range, and pressure/temperature to Flow Measurement Services for a quote. Specifications summarized from Smith Meter bulletin SSKS004; confirm current data with the factory before ordering.
Smith Meter (formerly FMC Technologies / TechnipFMC Measurement Solutions), now manufactured by Guidant. Flow Measurement Services supplies and services Smith Meter equipment.