The Smith Meter Fmc2 Flow Management Computer is a user-programmable, microprocessor-based instrument that monitors and controls the flow of liquid and gas petroleum products, either as a stand-alone flow computer or as a building block in a supervisory control system. An 8-inch touch-screen HMI drives scalable Field Input/Output Blocks (FIOBs). One software version handles gas or liquid, US or metric units, and mixed fluid types per meter run, and it supports PD, conventional and helical turbine, ultrasonic and orifice meters for pipeline and batch deliveries and proving.

Key specifications

  • Capacity: Up to 6 dual-pulse meter runs, with analog I/O and RTD modules, master meter, bidirectional prover and frequency densitometer inputs
  • Functions: Current and historical API and AGA standards (including ethanol per Brazilian specs); automatic proving with displacement and master-meter provers; 12-point meter factor linearization; statistical meter-factor control; PI loop control; MOV run sequencing; dual/triple redundancy; condition-based monitoring; trending; 100 archived records per report type
  • HMI: 8 in panel-mount touch screen, 800 x 600, 16-bit color, 32-bit CPU; cutout 8.69 x 7.25 in (221 x 184 mm); 24 VDC, 5 A max.; 0 to 50 °C
  • FIOB (MTR-AI-FI): 14.76 x 4.75 x 3.5 in; 24 VDC +20/-15%, 3 A max. per meter run; 0 to 55 °C; ordinary (non-hazardous) locations
  • Communications: 1 EIA-232 and 1 EIA-422/485 port (to 115k baud); 2 Ethernet 10/100; Modbus master and slave (ASCII, RTU, TCP); USB file transfer
  • Pulse inputs: 24 VDC, optically isolated, 0 to 10 kHz; pulse fidelity checking per IP Level A or B
  • Analog I/O: Inputs 0-20 mA / 0-10 VDC, ±0.02% of range, >14 bit; outputs 0-20 mA / 0-10 VDC, ±0.01% (current) / ±0.008% (voltage)
  • RTD inputs: Pt100, Ni, Cu, 10-3000 Ω, 3- or 4-wire
  • Digital I/O: Optically isolated inputs (24 VDC typical); Form C relay outputs, 250 V, 3 A
  • Languages: English, Russian, Spanish, Portuguese, French
  • Approvals: OIML R-117-1; EN-12405-1(/A1); GOST pattern approval; UL/CE; FCC (display)

How to specify / order

The bulletin gives no model code. Provide with your RFQ:

  • Number of meter runs (up to 6) and meter types (PD, turbine, ultrasonic, orifice) for each
  • Liquid, gas or mixed service, products and measurement standards required
  • Prover type (bidirectional, master meter) and densitometer, pressure and temperature inputs
  • Control needs: flow/pressure PI loops, MOV sequencing, sampler, redundancy (dual or triple)
  • Communication to SCADA/host (Modbus serial or TCP) and optional Remote HMI software

Bulletin notes: the RTD accuracy is printed "+/-0.2°F, +/-0.83 maximum" with no unit on the second value; the HMI and the FIOB are both listed at 3.9 lb (1.77 kg); "Proportion/Integral" and "typcal" typos.

Pricing and lead time are quoted per configuration. Send the model number (or the details above) with your meter model and serial number to Flow Measurement Services for a quote. Specifications summarized from Smith Meter bulletin SS09042 Rev 0.2 (09/10); confirm current data with the factory before ordering.

Smith Meter (formerly FMC Technologies / TechnipFMC Measurement Solutions), now manufactured by Guidant. Flow Measurement Services supplies and services Smith Meter equipment.

Smith Meter Fmc2 Flow Management Computer

0,00 $Preis
exkl. MwSt. |
Anzahl
    FMS Logo White and Blue png.png
    • YouTube
    • LinkedIn
    • Instagram
    • Facebook
    • Twitter
    • Discord
    Daniel Measurement & Control, Emerson, Technip FMC Smith, Honeywell, Enraf, TopTech, Varec, Endress Hauser, Krohne, OPW, Excel Loading Systems, Emco Wheaton, Brodie, Faure Herman, Sensia, OMNI, ABB, Dynamic Flow Computers, Welker, Clif Mock, Ametek, Phase Dynamics, Titan Solutions, ASI Additive Systems Inc, Scully, GSI Gauging Systems, L&J, Blackmer, Viking Pump, FlowServe, Sulzer, DNOW, Sundyne, Griswold, ROPER, Corken, Smith Pumps, Gorman Rupp, John Crane, Goulds, Tuthill, Wilden, Yamada, Liquid Controls, FlowMD, Meter Engineers, TCS Total Control Systems, Veeder Root, Westech Industrial, SafeRack, Carbis, Safe Harbor, ErectaStep, Greenline, FlowTech, Fisher, Valtek, Rexa, Limitorque, Rotork, Dan Ex Western Valve, General Valve Twin Seal, Apollo Valve, IFC Islip, Asco, ATMOS, K-Patents, Flexim, Siemens, Allen Bradley, Wonderware, Swagelok, Magnetrol, CCS Custom Control Sensors, Armstron, Gammon, Fill Rite, Neptune, Liqua Tech, Hannay Reels, Coxreels, Wilcox Hose, Smart Hose, Jamison, Jenson Mixers, KEP Kessler Ellis Products, Precision Digital, API Coupler, Loading Arm, Truck Loading, Offloading, Additive Injection, Blending, PD Meter, Turbine Meter, Ultrasonic Meter, Coriolis Meter, Custody Transfer, NTEP Weights and Measures, Sampling, Mixing, Terminal Automation, PLC, RTU, Tank Gauging, Pipeline, Barge, Rail, 

    © 2026 Flow Measurement Services

    bottom of page