The INVALCO Model 4200 is a programmable, intrinsically safe flow rate indicator and resettable totalizer in a NEMA 4X weatherproof, corrosion-resistant polycarbonate (Luran S) enclosure. It accepts frequency or pulse inputs from a wide range of flowmeters and displays rate and total in engineering units. It mounts directly on the flowmeter (swivel stem), on a wall with a pivoting bracket, or in a panel. Versions: battery powered with scaled pulse output, or loop powered with a 4-20 mA rate output.
Key specifications
- Display: Continuously powered LCD; total and rate six digits, 0.5" high; rollover count screen for totals of 1,000,000 or more
- K-factor: Programmable 0.001 to 999,999 pulses per unit, with multi-point linearization
- Timebase: Units per second, minute, hour or day
- Input: 0-4,250 Hz; sine wave (20 mV p-p min.), pulse, reed switch and others
- Battery version: One D-size 3.6 V lithium pack; about five years typical without the scaled pulse output
- Loop-powered version: 2-wire 4-20 mA, programmable 4 and 20 mA points, 0.05% of span, 1.0 s response, 35 VDC max. across output
- DC power / pulse output: 8-35 VDC @ 20 mA min.; scaled pulse, 100 ms @ 5 Hz max.
- Approval: Intrinsically safe Class I Div 1 Groups A, B, C, D (CUL/UL) - see note on the loop-powered version
- Operating temperature: -40 to 158 °F (-40 to 70 °C)
- Enclosure: 7.5" H x 8.0" W x 2.9" D; cable gland entry; password protection
How to read the model code
Example: 4200-30. Read the code left to right; each position selects one option:
- Base: 4200 field-mounted rate/totalizer
- Mounting (first digit): 1 = standard weatherproof wall mount / panel mount; 3 = standard weatherproof swivel meter-mount stem, 1" FNPT
- Power / output (second digit): 0 = battery (lithium) powered, pulse output; 1 = loop powered with 4-20 mA rate output
Bulletin issues to confirm with the factory: the features list states CUL/UL intrinsic safety, but the loop-powered 4-20 mA section says "CUL/UL Pending" and is footnoted "Non UL Approved"; the intro and specs describe an 8-35 VDC powered scaled-pulse version, but the model designation only covers battery (x0) and loop-powered (x1) versions; and the loop accuracy is printed as 0.01% of total +/- 1 count.
Pricing and lead time are quoted per configuration. Send the model code (or your application details), product, flow range, and pressure/temperature to Flow Measurement Services for a quote. Specifications summarized from Smith Meter (INVALCO) bulletin SSIN036 Rev 0.1 (11/18); confirm current data with the factory before ordering.
Smith Meter (formerly FMC Technologies / TechnipFMC Measurement Solutions), now manufactured by Guidant. Flow Measurement Services supplies and services Smith Meter equipment.