The Smith Meter Ultra 6 is a six-path transit-time ultrasonic flowmeter for custody transfer, allocation, line balancing and leak detection on refined products and crude oil. Flush-mounted titanium transducers leave the bore unobstructed, so pressure drop equals that of straight pipe and there are no moving parts to wear. The six-path layout and strong noise immunity hold accuracy on high-viscosity crude with changing flow profiles, and transducers can be replaced in-line without shutting down.
Key specifications
- Sizes: 6, 8, 10, 12, 14, 16, 18 and 20 in (larger on request)
- Normal flow range: 6 in: 450-4,500 BPH; 8 in: 800-8,000 BPH; 10 in: 1,250-12,500 BPH; 12 in: 1,900-19,000 BPH; 16 in: 2,800-28,000 BPH; 20 in: 4,200-42,000 BPH (extended range to about 1.2x max)
- Linearity / repeatability: ±0.15% over normal range / ±0.02%; complies with API MPMS 5.8 and OIML R117-1
- Viscosity: 0.5 cSt minimum; maximum from 800 cSt (6 in) to 200 cSt (20 in) standard, higher with low-frequency transducers on 12 in and up
- Flow direction: Bidirectional
- Pressure: ASME Class 150-900 RF or RTJ flanges (285 to 2,220 psi carbon steel)
- Temperature: Process -50 to 250 °F (CS body); ambient -40 to 140 °F
- Materials: Carbon steel body (stainless optional); titanium-encapsulated piezoelectric transducers; NACE design
- Electronics / I/O: 24 VDC or 120/240 VAC; 4 pulse outputs (0-5 kHz, quadrature), 2 digital in/out, up to 2 analog I/O, Ethernet Modbus TCP, 2 serial Modbus RTU ports; WinScreen diagnostics
- Approvals: CSA/UL Class I Div 1 C&D, ATEX, IECEx; CRN
How to read the model code
Example: 6U0611S011CS. Read the code left to right; each position selects one option:
- Position 1 (Model): 6 = Ultra 6
- Position 2 (Certification): U = US model, explosion-proof (UL/CSA); A = European model, ATEX/IECEx
- Positions 3-4 (Diameter): 06, 08, 10, 12, 14, 16, 18, 20 (inches)
- Position 5 (End connections): 1 = Cl 150 RF; 2 = Cl 300 RF; 3 = Cl 600 RF; 4 = Cl 900 RF; 5-8 = Cl 150/300/600/900 RTJ
- Position 6 (Materials): 1 = carbon steel; 2 = 300-series stainless; X = special
- Position 7 (Transducer): S = standard titanium; X = special
- Position 8 (Optional interface): 0 = not required
- Position 9 (Analog inputs (max 2 analog I/O total)): 0 = none; 1 = one 4-20 mA; 2 = two 4-20 mA; 3 = one 1-5 VDC; 4 = two 1-5 VDC; 5 = one RTD; 6 = one 4-20 mA + one RTD; 7 = one 1-5 VDC + one RTD
- Position 10 (Analog outputs): 0 = none; 1 = one 4-20 mA; 2 = two 4-20 mA; 3 = one 1-5 VDC; 4 = two 1-5 VDC
- Position 11 (Mechanical certification): B = ASME B31.3; P = PED; C = CRN; X = special
- Position 12 (Software): S = standard; X = special
Pricing and lead time are quoted per configuration. Send the model code (or your application details), product, flow range, and pressure/temperature to Flow Measurement Services for a quote. Specifications summarized from Smith Meter bulletin SSLS001; confirm current data with the factory before ordering.
Smith Meter (formerly FMC Technologies / TechnipFMC Measurement Solutions), now manufactured by Guidant. Flow Measurement Services supplies and services Smith Meter equipment.