Specifications
Line Size DN25 to DN100 (1-in to 4-in)
Fluid Type Liquid
Linearity (standard) 1-in to 2-in: 0.25%; 3-in to 4-in: 0.15%
Repeatability ±0.02%
Process Temperature Range (standard)Carbon Steel, ASTM A352 GR LCC
Materials: Valve Cylinder• Carbon Steel: -29 C to +60 C (-20 F to +140 F)
• Stainless Steel: -40 C to +60 C (-40 F to +140 F)
Operating Pressure Range PN20 to PN50 (ANSI 150 to 300)
Materials Carbon steel and stainless steel
Electronics 1 or 2 pickoff coils and Dual-Channel Preamplifier (standard)
Features
-
Ensure fiscal measurement accuracy with pulse output linear with flow rate and 10:1 rangeability (turndown)
-
Maximize accountability with high-frequency pulse resolution that enables measurement of minute increments
-
Achieve maximum volume throughput and minimum pressure drop with high-performance stainless steel internal assembly
Features
-
Eliminate missing or double-counted pulses by achieving total pulse integrity with optional second pickoff coil
-
Simplify maintenance with new threaded lid that allows easy access to preamplifier and pickoff coil(s)
-
Easily upgrade UMB-equipped meters to the new LME housing that features potted electronics to improve durability
Features
-
Rely on stainless steel or tungsten journal carbide bearings to improve durability and minimize maintenance
-
Confidently use within the guidelines of API MPMS, Chapter 4 (proving) and Chapter 5.3 (measurement)