The Smith Meter Ultra 8c is an eight-path liquid ultrasonic flowmeter for custody transfer of refined products, LPG and light to heavy crude oils. Crossing measurement paths cancel swirl, so it installs with only 5D of upstream straight run and no flow conditioner, and dynamic profile compensation keeps it linear from laminar to turbulent flow. Flush, non-intrusive transducers sit in removable wells for replacement under pressure, with an optional low-frequency transducer for the heaviest and dirtiest fluids.
Key specifications
- Accuracy: ±0.12% linearity over the 15:1 normal flow range; repeatability ±0.02%; API MPMS 4.8 meter factor uncertainty ±0.027%
- Sizes / normal flow: 4": 150-2,200 bph; 6": 340-5,090; 8": 570-8,700; 10": 940-13,800; 12": 1,320-19,800; 16": 2,140-32,000; 20": 3,400-51,000; 24": 4,970-74,200; 30": 7,860-118,000 bph (extended range available)
- Viscosity: From 0.5 cSt; standard maximum 175-1,225 cSt depending on size, extended to 1,075-3,400 cSt on 12"-30" (consult factory)
- Installation: 5D upstream straight run after an elbow or reducer; 10D recommended downstream of control valves
- Pressure / temperature: ASME Class 150/300/600/900 RF or RTJ; carbon steel to 2,220 psi; fluid -50 to 250 °F (height extension above 158 °F)
- Approvals: MID MI-005, Welmec 7.2, OIML R117-1 Class 0.3, API 5.8, INMETRO; UL/cUL, ATEX, IECEx; NACE MR0175 design
- Standard I/O: 24 VDC; 2 x 4-20 mA in, 1 RTD, 1 x 4-20 mA out (optional HART); alarm output; 2 digital inputs; 2 pulse outputs 0-10 kHz with quadrature; 2 Ethernet (or fiber); 1 EIA-485 Modbus
- Calibration: Every meter dynamically tested on hydrocarbon at the Erie Flow Research and Test Center; optional multi-viscosity and ISO 17025 calibration
How to read the model code
Example: 8-S-06-1-1-S-S-B-C-40 with UMC-E-A-P-N-S-0-B-0. Read the code left to right; each position selects one option:
- Position 1 (Code): 8 = Ultra 8c
- Position 2 (Certification): S = standard UL/cUL, ATEX, IECEx; B = INMETRO UL Brazil
- Positions 3-4 (Diameter): 06, 08, 10, 12, 14, 16, 18, 20, 24, 26, 30 inch (other sizes or custom ID, consult factory)
- Position 5 (End connections): 1-4 = Class 150/300/600/900 ASME flange; 5-8 = Class 150/300/600/900 RTJ
- Position 6 (Body material): 1 = carbon steel; 2 = 300 series stainless; X = special
- Position 7 (Transducer): S = standard titanium; X = special (non-Buna-N service)
- Position 8 (Transducer type): S = standard; L = low frequency (high viscosity); H = high frequency
- Position 9 (Mechanical certification): B = ASME B31.3; P = PED; C = CRN; X = special
- Position 10 (Ethernet): C = 2 twisted pair; F = 1 twisted pair + 1 optical
- Positions 11-12 (Inlet ID / meter run schedule): 10, 20, 30, 40, 60, 80, ST (STD), XS, CD (custom ID)
- Electronics (UMC code): UMC-(E explosion-proof / B INMETRO)-(A aluminum / S stainless)-(P pedestal / H with height extension)-(M M20 / N 1/2" NPT)-S-0-(B blind / T 5.7" touchscreen)-(0 none / 1 HART)
- Remote display (optional): TCI-(E/B)-(A/S)-S-(M/N)-(S/X); see the Ultra Series Remote Touchscreen Display listing
Include the meter body and UMC codes on the purchase order.
Pricing and lead time are quoted per configuration. Send the model code (or your application details), product, flow range, and pressure/temperature to Flow Measurement Services for a quote. Specifications summarized from Smith Meter bulletin SSLS006; confirm current data with the factory before ordering.
Smith Meter (formerly FMC Technologies / TechnipFMC Measurement Solutions), now manufactured by Guidant. Flow Measurement Services supplies and services Smith Meter equipment.