The Smith Meter UPCC (Universal Performance Curve Compensator) is a microprocessor-based turbine meter preamplifier for Smith Meter MV Series multiviscosity turbine meters. It applies each meter's factory meter-factor versus velocity/viscosity curve in real time, using a constant viscosity, temperature-inferred viscosity, a 4-20 mA viscosity signal or a direct Solartron viscometer head. It also squares up the pickup signal for long cable runs and works as a small flow computer with rate, batch and cumulative totals.
Key specifications
- Viscosity input: Constant value, temperature/viscosity (RTD), 4-20 mA proportional to viscosity, or Solartron viscometer head (24 VDC supply required)
- Power: 12-24 VDC ±10%, under 250 mA at 24 V
- Signal input: Sinusoidal pickup (70 mVp-p sensitivity) or square wave; to 2,000 Hz
- Inputs: 3 status inputs, four-wire 100-ohm PRTD, one 4-20 mA input
- Outputs: 4 push-pull pulse outputs (2 raw, 2 programmable: compensated, high-resolution or quadrature), 2 open-collector switch outputs, 2 4-20 mA outputs
- Communications: EIA-232 or EIA-485 (DIP selectable), 1,200-19,200 bps, Modbus ASCII/RTU
- Environment: -58 to 158 °F (24 VDC needed below -4 °F); 0-95% RH non-condensing
- Approvals: UL/cUL Class I Groups C & D, AEx d IIB T6 IP66; ATEX/IECEx Ex d IIC T6 IP66
- Cable distance: Up to 2,400 ft (#20 AWG), 3,800 ft (#18) or 6,000 ft (#16)
How to read the model code
Example: UPCC-XU-STD. Read the code left to right; each position selects one option:
- Position 1 (Model): UPCC = Universal Performance Curve Compensator
- Position 2 (Housing): XU = UL/cUL listed; XC = ATEX / IECEx certified
- Position 3 (Firmware): STD = standard
When ordered with a new MV Series meter, the UPCC is specified in the meter catalog code (pickup position U or W, testing position C or D) so the meter is calibrated for viscosity compensation.
Pricing and lead time are quoted per configuration. Send the model code (or your application details), product, flow range, and pressure/temperature to Flow Measurement Services for a quote. Specifications summarized from Smith Meter bulletin SS02017; confirm current data with the factory before ordering.
Smith Meter (formerly FMC Technologies / TechnipFMC Measurement Solutions), now manufactured by Guidant. Flow Measurement Services supplies and services Smith Meter equipment.