The Smith Meter Ultra 4 is a four-path transit-time liquid ultrasonic flowmeter with a signal processing unit, used for measurement of refined products and crude oil in pipeline, inventory, allocation, line-balancing and leak-detection service. It shares its electronics and transducer design with the Ultra 6 and MPU gas meters. The non-intrusive, flush-mounted titanium transducers leave a full open bore, with no moving parts and pressure drop equal to straight pipe. Sizes run up to 48 inches.
Key specifications
- Sizes: 6 through 48 in (6, 8, 10, 12, 14, 16, 18, 20, 22, 24, 26, 28, 30, 32, 34, 36, 40, 48)
- Normal flow range: 6 in: 450-4,500 BPH; 12 in: 1,900-19,000 BPH; 24 in: 6,500-65,000 BPH; 36 in: 15,000-150,000 BPH; 48 in: 26,000-260,000 BPH (extended to about 1.2x)
- Linearity / repeatability: ±0.25% over normal range / ±0.02%
- Viscosity: 0.5 cSt minimum; maximum from 800 cSt (6 in) to 80 cSt (48 in) standard
- Flow direction: Bidirectional
- Pressure: ASME Class 150-900 RF or RTJ (285 to 2,220 psi carbon steel)
- Temperature: Process -50 to 250 °F (CS body); ambient -40 to 140 °F
- Electronics / I/O: Same SPU as Ultra 6: 24 VDC or 120/240 VAC, 4 pulse outputs, Ethernet and serial Modbus, up to 2 analog I/O
How to read the model code
Example: 4RU0611S011CS. Read the code left to right; each position selects one option:
- Position 1 (Model): 4 = Ultra 4
- Position 2 (Certification / service (two characters)): RU = refined & light crude, US explosion-proof; RA = refined & light crude, ATEX/IECEx; CD = crude oil, US explosion-proof; CA = crude oil, ATEX/IECEx
- Positions 3-4 (Diameter): 06 through 48 (inches)
- Position 5 (End connections): 1-4 = Class 150/300/600/900 RF; 5-8 = Class 150/300/600/900 RTJ
- Position 6 (Materials): 1 = carbon steel; 2 = 300-series stainless; X = special
- Position 7 (Transducer): S = standard titanium; X = special
- Position 8 (Optional interface): 0 = not required
- Position 9 (Analog inputs (max 2 analog I/O total)): 0 = none; 1 = one 4-20 mA; 2 = two 4-20 mA; 3 = one 1-5 VDC; 4 = two 1-5 VDC; 5 = one RTD; 6 = one 4-20 mA + one RTD; 7 = one 1-5 VDC + one RTD
- Position 10 (Analog outputs): 0 = none; 1 = one 4-20 mA; 2 = two 4-20 mA; 3 = one 1-5 VDC; 4 = two 1-5 VDC
- Position 11 (Mechanical certification): B = ASME B31.3; P = PED; C = CRN; X = special
- Position 12 (Software): S = standard; X = special
Pricing and lead time are quoted per configuration. Send the model code (or your application details), product, flow range, and pressure/temperature to Flow Measurement Services for a quote. Specifications summarized from Smith Meter bulletin SSLS002; confirm current data with the factory before ordering.
Smith Meter (formerly FMC Technologies / TechnipFMC Measurement Solutions), now manufactured by Guidant. Flow Measurement Services supplies and services Smith Meter equipment.