The Smith Meter Model 296-40A Valve is used with Smith Meter preset counters for preset loading at loading racks, bulk plants and processing installations. It is a 200 Series valve with two solenoids (N.O. 30B and N.C. 30A), a position stem switch, a sensitivity needle valve and a 40A flow limiting pilot that senses differential pressure across an integral orifice plate. It is typically controlled by the microswitch assembly of a mechanical set-stop counter in the accessory stack of a PD meter: the valve opens toward full open, limits maximum flow rate through the 40A pilot, drops to a hydraulically locked low-flow mode at the first-stage trip and closes at the final trip.
Key specifications
- Sizes / nominal flow: 2" 130 USGPM (492 L/min); 3" 420 (1,600); 4" 600 (2,250); 6" 1,000 (3,750); larger sizes consult factory
- Maximum operating pressure: 115 psig (793 kPa) standard; 150 psig (1,034 kPa) optional; 285 psig (Class 150) or 300 psig (Class 300) optional - limited by the solenoids
- Maximum viscosity: Up to 200 SSU (40 cP); above that use the Model 215 (SS03010)
- Temperature: Buna-N elastomers -20 to 160 °F (-29 to 71 °C); Viton 10 to 350 °F (-12 to 177 °C)
- Solenoid voltage: Standard 102-120 VAC 60 Hz or 94-110 VAC 50 Hz; optional 204-240 VAC 60 Hz, 50 Hz high-voltage, or 24 VDC
- Materials: Cast steel main valve (stainless, steel, ductile iron internals; Buna-N or Viton); stainless solenoid valves (Viton, Buna-N or Chemraz); steel needle valve with PTFE; carbon steel pilot
- Weight: 2" 46 lb (21 kg); 3" 83 lb (38 kg); 4" 136 lb (62 kg); 6" 258 lb (117 kg)
- Options: 15AXM low flow start timer, pre-wired junction box, check / thermal relief, 03A manual override, control loop isolation, 64A truck manifold pressure limiting (bottom loading), pressure reducing control
How to specify / order
The bulletin has no position-by-position model code. To quote, send:
- Valve size (2"-6") and flange class (Class 150 or 300)
- Required maximum operating pressure (115, 150 or full flange rating), which sets the solenoid choice
- Product, viscosity and maximum flow rate setting (for orifice plate sizing)
- Elastomers and solenoid voltage
- Options from the list above, and the meter / set-stop counter it will work with
Bulletin notes: pages 2-3 carry the footer of a different bulletin ("SS03043 Issue/Rev. 0.5"); weights are printed with inch marks (e.g. 46"); the optional 50 Hz high voltage is printed "118 - 220 Vac" (probably 188-220); page 1 also shows a "296-50B-40A" figure label not explained in the text. For the mechanical set-stop valve see SM-SET-STOP-VALVE.
Pricing and lead time are quoted per configuration. Send the model code (or the details above) with your product and operating conditions to Flow Measurement Services for a quote. Specifications summarized from Smith Meter bulletin SS03019 Rev 0.1 (8/17); confirm current data with the factory before ordering.