The Smith Meter MPU 1200 Series B is a six-path (12-transducer) ultrasonic gas flowmeter with non-intrusive, flush-mounted titanium transducers for custody transfer of dry, high-pressure gas onshore and offshore. Its path layout compensates for swirl and crossflow, giving bidirectional measurement with ±0.1% uncertainty when flow calibrated. Digital signal processing tolerates high ultrasonic noise, and transducers can be retracted under pressure without shutdown or recalibration. Sound-velocity, density and full diagnostics are available through WinScreen software.
Key specifications
- Paths: 6 paths / 12 transducers; bidirectional with swirl and crossflow compensation
- Accuracy: Flow calibrated ≤ ±0.1%; dry calibration ≤ ±0.5%; repeatability ≤ ±0.05%; AGA 9 and ISO 17089
- Velocity range: 6-16": 0.4-30 m/s; 18-30": 0.3-26 m/s; 32-56": 0.2-20 m/s
- Installation: 3D + flow conditioner + 7D upstream, 3D downstream (3D + FC + 5D each side for bidirectional)
- Pressure / temperature: 1-275 bar a (to 3,990 psia, higher on request); gas -4 to 158 °F; ambient -13 to 140 °F
- Construction: Carbon or stainless steel spool; ANSI B16.5 RF or RTJ flanges Class 150 to 2500; titanium-encapsulated piezo transducers
- Power: 24 VDC (0.5 A) or 120/240 VAC, 12 W
- I/O: 2 digital inputs, 2 digital outputs, 4 pulse outputs to 5 kHz (single or dual quadrature), up to 2 analog in/out (4-20 mA or 1-5 VDC)
- Communications: 10/100 Ethernet (twisted pair or fiber), two RS-232/485 ports, Modbus RTU
- Approvals: UL/cUL Class I Div 1 Groups C & D; ATEX Eex d IIB T5
How to read the model code
Example: MPU-12-U-12-3-R-0-D-1-0-0. Read the code left to right; each position selects one option:
- Model: 12 = MPU 1200 (6-path); 8 = MPU 800; 6 = MPU 600; 2 = MPU 200
- Certification: U = US model, explosion-proof (UL/cUL); A = European model, ATEX
- Diameter: Nominal size in inches (06 = 6", 12 = 12", etc.)
- Flanges: 1 = 150; 2 = 300; 3 = 400; 4 = 600; 5 = 900; 6 = 1500; 7 = 2500
- Transducer: S = standard; R = retractable under pressure
- Optional interfaces: 0 = not required; F = fiber optic Ethernet (100Base-FL)
- Local display: 0 = not required; D = with local display
- Analog input: 0 = none; 1 = one 4-20 mA; 2 = two 4-20 mA; 3 = one 1-5 VDC; 4 = two 1-5 VDC (max 2 analog I/O total)
- Analog output: 0 = none; 1 = one 4-20 mA; 2 = two 4-20 mA; 3 = one 1-5 VDC; 4 = two 1-5 VDC
- Additional communication board: 0 = not required; C = with additional board
Include the catalog code on the purchase order. Submit gas composition, pressure, temperature and flow range for sizing.
Pricing and lead time are quoted per configuration. Send the model code (or your application details), product, flow range, and pressure/temperature to Flow Measurement Services for a quote. Specifications summarized from Smith Meter bulletin SSKS002; confirm current data with the factory before ordering.
Smith Meter (formerly FMC Technologies / TechnipFMC Measurement Solutions), now manufactured by Guidant. Flow Measurement Services supplies and services Smith Meter equipment.