The Smith Meter MPU 600 Series B is a three-path ultrasonic gas flowmeter with non-intrusive, flush-mounted titanium transducers for dry, high-pressure gas at terminals, mixing stations, power plants, compressor stations and pipeline nodes. It meets AGA 9 performance when installed with long upstream piping or a flow conditioner, and shares the MPU family's digital signal processing, in-line transducer retraction, pressure/temperature compensation and WinScreen diagnostics.
Key specifications
- Paths: 3 paths; bidirectional
- Accuracy: Flow calibrated ≤ ±0.3%; dry calibration ≤ ±0.7%; repeatability ≤ ±0.10% (requires a well-developed flow profile)
- Velocity range: 4-16": 0.4-30 m/s; 18-30": 0.3-26 m/s; 32-56": 0.2-20 m/s
- Pressure / temperature: 1-275 bar a (to 3,990 psia, higher on request); gas -4 to 158 °F; ambient -13 to 140 °F
- Construction: Carbon or stainless steel spool; ANSI B16.5 RF or RTJ flanges Class 150 to 2500; titanium-encapsulated piezo transducers
- Power: 24 VDC (0.5 A) or 120/240 VAC, 12 W
- I/O: 2 digital inputs, 2 digital outputs, 4 pulse outputs to 5 kHz (single or dual quadrature), up to 2 analog in/out (4-20 mA or 1-5 VDC)
- Communications: 10/100 Ethernet (twisted pair or fiber), two RS-232/485 ports, Modbus RTU
- Approvals: UL/cUL Class I Div 1 Groups C & D; ATEX Eex d IIB T5
How to read the model code
Example: MPU-6-U-06-1-S-0-0-0-0-0. Read the code left to right; each position selects one option:
- Model: 12 = MPU 1200 (6-path); 8 = MPU 800; 6 = MPU 600; 2 = MPU 200
- Certification: U = US model, explosion-proof (UL/cUL); A = European model, ATEX
- Diameter: Nominal size in inches (06 = 6", 12 = 12", etc.)
- Flanges: 1 = 150; 2 = 300; 3 = 400; 4 = 600; 5 = 900; 6 = 1500; 7 = 2500
- Transducer: S = standard; R = retractable under pressure
- Optional interfaces: 0 = not required; F = fiber optic Ethernet (100Base-FL)
- Local display: 0 = not required; D = with local display
- Analog input: 0 = none; 1 = one 4-20 mA; 2 = two 4-20 mA; 3 = one 1-5 VDC; 4 = two 1-5 VDC (max 2 analog I/O total)
- Analog output: 0 = none; 1 = one 4-20 mA; 2 = two 4-20 mA; 3 = one 1-5 VDC; 4 = two 1-5 VDC
- Additional communication board: 0 = not required; C = with additional board
Include the catalog code on the purchase order. Submit gas composition, pressure, temperature and flow range for sizing.
Pricing and lead time are quoted per configuration. Send the model code (or your application details), product, flow range, and pressure/temperature to Flow Measurement Services for a quote. Specifications summarized from Smith Meter bulletin SSKS003; confirm current data with the factory before ordering.
Smith Meter (formerly FMC Technologies / TechnipFMC Measurement Solutions), now manufactured by Guidant. Flow Measurement Services supplies and services Smith Meter equipment.