The Smith Meter Ultra 6c is the current-generation six-path liquid ultrasonic flowmeter for custody transfer of light, medium and heavy petroleum liquids at terminals, on pipelines and offshore (FPSO and platforms). Its six-path layout measures and corrects for crossflow and swirl, and an optional low-frequency transducer keeps signal strength on high-viscosity or contaminated crude and during cold starts. It is paired with the UMC meter-mounted electronics, which can carry a 5.7-inch color touch screen, and every meter is flow-tested on hydrocarbon at the factory.
Key specifications
- Sizes: 4, 6, 8, 10, 12, 16, 20, 24 and 30 in standard (others on request)
- Normal flow range: 6 in: 420-4,210 BPH; 8 in: 730-7,300 BPH; 12 in: 1,650-16,500 BPH; 16 in: 2,670-26,700 BPH; 24 in: 6,200-62,000 BPH; 30 in: 9,810-98,100 BPH
- Linearity / repeatability: ±0.15% over normal range / ±0.02%; average meter-factor uncertainty ±0.027% per API MPMS 4.8
- Approvals: MID MI-005, OIML R117-1 Class 0.3, WELMEC 7.2, API MPMS 5.8; UL/cUL, ATEX, IECEx
- Viscosity: 0.5 cSt minimum; maximum from 1,225 cSt (6 in) down to 175 cSt (30 in) standard, higher with low-frequency transducers
- Pressure: ASME Class 150-900, RF or RTJ flanges
- Materials: Carbon steel or 300-series stainless body; titanium transducers in removable wells (replaceable under pressure)
- Standard I/O: 24 VDC; 2 pulse outputs (0-10 kHz, quadrature); 2 analog in (4-20 mA) + RTD in; 1 analog out; 2 Ethernet; EIA-485; optional HART
How to read the model code
Example: 6S0611SSBC-40. Read the code left to right; each position selects one option:
- Position 1 (Model): 6 = Ultra 6c
- Position 2 (Hazardous-location certification): S = UL/cUL, ATEX, IECEx
- Positions 3-4 (Diameter): 06, 08, 10, 12, 14, 16, 18, 20, 24, 25, 30 (inches)
- Position 5 (End connections): 1-4 = Class 150/300/600/900 RF; 5-8 = Class 150/300/600/900 RTJ
- Position 6 (Body material): 1 = carbon steel; 2 = 300-series stainless; X = special
- Position 7 (Transducer material): S = standard titanium; X = special
- Position 8 (Transducer type): S = standard; L = low frequency (high viscosity)
- Position 9 (Mechanical certification): B = ASME B31.3; P = PED; C = CRN; X = special
- Position 10 (Ethernet): C = 2 twisted pair; F = 1 twisted pair + 1 optical
- Positions 11-12 (Inlet ID (meter run schedule)): 10, 20, 30, 40, 60, 80, ST (STD), XS, CD (custom)
- Electronics (UMC enclosure code): UMC-E-(A aluminum / S stainless)-(P pedestal / H high-temp extension / E Ex e box)-(M M20 / N 1/2 in NPT)-S-0-(B blind / T touch screen)-(0 none / 1 HART)
Pricing and lead time are quoted per configuration. Send the model code (or your application details), product, flow range, and pressure/temperature to Flow Measurement Services for a quote. Specifications summarized from Smith Meter bulletin SSLS004; confirm current data with the factory before ordering.
Smith Meter (formerly FMC Technologies / TechnipFMC Measurement Solutions), now manufactured by Guidant. Flow Measurement Services supplies and services Smith Meter equipment.